Old Legacy Server Sizing

From Observer GigaFlow Support | VIAVI Solutions Inc.
Revision as of 12:23, 30 September 2016 by Kevin Wilkie (Talk | contribs)

Jump to: navigation, search

Anuview Flow has been tested and certified to support up to 1000 concurrent devices or up to 40k flows/s from < 20 devices.

Below we can see as more devices are added to the system, the supported flow rate decreases in proportion.

Flowspersecperdevicecount.png

The server must support at least 100MB/s sustained for both read and write to support the peak device of flow count.

Failing to do so will result in dropped flow details.

A base installation should have 4GB or RAM available for the OS and and additional 50MB per device to monitor. More ram will always improve performance e.g

Number Of Devices Min Ram
10 4.5GB
100 9GB
500 29GB
1000 54GB